Measurement of Vicat softening point temperature during hot deformation

تفاصيل المنتج

热变形维卡.jpg

overview

The XRW-300C series hot deformation and Vicat softening point temperature measuring instrument is widely used in plastic chemical enterprises and research institutions to adapt to the rapid development of the plastic industry and improve the research and testing level of materials. This system is controlled by PLC, making the performance of the product more stable, easy to operate, and highly automated. It is currently one of the more advanced detection instruments used for deformation and softening temperature of non-metallic materials in China.
XRW-300C: PLC control, vertical machine (sample rack can be automatically raised and lowered); Sample work positions: three, four, six (customizable)
Compliant with standards
ISO75-1:1993 "Plastics - Determination of deformation temperature under load" ISO306:1994 "Plastics - Determination of Vicat softening point temperature of thermoplastic plastics"
GB/T1633-2000 "Determination of Vicat softening point temperature of thermoplastic materials"
GB/T1634-2001 "Plastics - Determination of Load Deformation Temperature"
Technical Parameter

1. Temperature range: Room temperature -300 ℃
2. Heating rate: 120 ± 10 ℃/h (12 ℃± 1 ℃/6min)
50 ± 5 ℃/h (5 ℃± 0.5 ℃/6min)
3. Temperature error: ± 1 ℃ Deformation error: ± 0.01mm
4. Temperature resolution: 0.1 ℃ deformation resolution 0.01mm
5. Load range: 0.864N-49.03N Load error: ± 2.5%
6. Deformation measurement method: displacement sensor
7. Deformation measurement range: 0-1.000mm
8. Deformation error: 0.005mm
9. Display accuracy: 0.001 mm
10. Test stand span: 60-180mm (suitable for thermal deformation testing)
11. Heating power: 4KW
12. Power supply voltage: AC220V/50Hz 20A
13. Heating medium: Methyl silicone oil (flash point at 300) Cooling method: Natural cooling above 150 ℃, water cooling below 150 ℃
Note: Grade A silicone oil customers should prepare it themselves