البريد الإلكتروني
2830308090@qq.com
-
الهاتف
17610821926
-
العنوان
Room 508, 5th Floor, Building A, No. 624 Beibaoxing Road, Jing'an District, Shanghai
Kaipu Technology (Shanghai) Co., Ltd
2830308090@qq.com
17610821926
Room 508, 5th Floor, Building A, No. 624 Beibaoxing Road, Jing'an District, Shanghai
ØLimited funds, no money to buy instruments and equipment?
ØThe project cycle is short, and after completing one stage of the experiment, the project will be concluded. Are you worried about the equipment being put on hold in the future?
ØAmidst the current pandemic, engineers are restricted from installing new instruments or repairing faulty ones on-site?
ØCan the existing instruments in the laboratory not meet the current surge in sample testing?
ØUrgent need to carry out new project experiments, but the process of purchasing new instruments is complex and the delivery time is long?
ØPlanning to entrust the testing center, but unable to queue up and meet the timeliness?
ØPlanning outsourcing cannot meet confidentiality requirements?
ØDo you want to personally produce data reports for greater peace of mind?
urgentThe urgent needs of customers,thinkWhat customers want, leasing/testinghelp力
Target audience:
Teacher from the University Analysis and Testing Center
University research group
Group of college graduates
Sample testing institution
Enterprise R&D and Quality Inspection Center
rental service
1. Diverse choices: We offer Setline DSC、Setline STA、Setline TGAThree standard instruments to meet your different testing application needs;
2. Signing agreement: Sign a rental service agreement with the user on a monthly basis as the minimum time unit;
3. Self installation: Breaking the conventional practice of requiring engineers to come and install traditional instruments, we have developed and upgraded our system specifically for the epidemic, eliminating the need for engineers to come and allowing users to install independently and enjoy the installation experience;
4. Lease term: shortest lease term2Within one month, the total rental amount reaches the selling price of the instrument, and the ownership of the instrument belongs to the user;
5. Zero maintenance premium: You do not need to bear additional normal maintenance costs during the lease period.
Sample testing service
1, Setline Test Type - Differential Scanning CalorimeterDSC/Thermogravimetric AnalyzerTGA/Synchronous Thermal Analyzer STA
| project | Testing service fee | Types of Atmosphere | heating rate ℃/min | temperature range ℃ | Crucible selection | Test content |
| DSC | 80.00/hour | N2 | 0.1-20 |
Room temperature~700 | 30ul aluminum crucible | Labeling of DSC reaction peaks: extrapolation of starting temperature, peak temperature, termination temperature, and calculation of peak area integral enthalpy value labeling. |
| TGA | 80.00/Hour by hour | 1-20 |
Room temperature~1100 | 170Aluminum oxide crucible | TG weight loss step annotation, weight loss%, weight loss absolute value annotation calculation, residual mass annotation, differential calculation of thermogravimetric curve (DTG). | |
| STA | 100.00/hour | 90ul alumina crucible | Synchronize measurement of heat flow and quality change data, with the same content as DSCandTGA | |||
| In addition to exporting the analyzed curve images in JPEG format, we also provide raw data exported in EXCEL and TXT formats. | ||||||
2. Testing service process
a)Customer sent: The client prepares the sample (clearly stating the sample number, experimental requirements, and contact information))And send it out;
b)Receipt confirmation: After receiving the sample, the laboratory will have the analyst confirm the experimental requirements by phone and conduct experimental analysis;
c)Experimental notification: Notify the client to make payment after the experiment is completed;
d)Flexible payment: bank card, WeChat, Alipay;
e)Data transmission: After confirming the remittance, send the data analysis report to the designated client via emailThe mailbox.
Example: The School of Materials Science and Technology at Beijing University of Science and Technology plans toSTAtest1A sample, nitrogen protection, room temperature to800℃,10K/minHeat up, no need to cool down, use ceramic crucible. The cost calculation is as follows:
800/10K/60min≈1.3hour
1.3x100=130.00yuan/sample
المقالة الأخيرة:National subsidized loan | Setram helps upgrade and renovate your thermal analysis instrument